On the promotion of cogeneration based on a useful heat demand in the internal energy market
ANNEX II

ANNEX II — Calculation of electricity from cogeneration

Values used for calculation of electricity from cogeneration shall be determined on the basis of the expected or actual operation of the unit under normal conditions of use. For micro-cogeneration units the calculation may be based on certified values.

(a) Electricity production from cogeneration shall be considered equal to total annual electricity production of the unit measured at the outlet of the main generators;

(i) in cogeneration units of type (b), (d), (e), (f), (g) and (h) referred to in Annex I, with an annual overall efficiency set by Member States at a level of at least 75 %, and

(ii) in cogeneration units of type (a) and (c) referred to in Annex I with an annual overall efficiency set by Member States at a level of at least 80 %.

(b) In cogeneration units with an annual overall efficiency below the value referred to in paragraph (a)(i) (cogeneration units of type (b), (d), (e), (f), (g), and (h) referred to in Annex I) or with an annual overall efficiency below the value referred to in paragraph (a)(ii) (cogeneration units of type (a) and (c) referred to in Annex I) cogeneration is calculated according to the following formula:

E CHP = HCHP. C

where:

E CHP

is the amount of electricity from cogeneration

C

is the power to heat ratio

HCHP

is the amount of useful heat from cogeneration (calculated for this purpose as total heat production minus any heat produced in separate boilers or by live steam extraction from the steam generator before the turbine).

The calculation of electricity from cogeneration must be based on the actual power to heat ratio. If the actual power to heat ratio of a cogeneration unit is not known, the following default values may be used, notably for statistical purposes, for units of type (a), (b), (c), (d), and (e) referred to in Annex I provided that the calculated cogeneration electricity is less or equal to total electricity production of the unit:

Type of the unit

Default power to heat ratio, C

Combined cycle gas turbine with heat recovery

0,95

Steam backpressure turbine

0,45

Steam condensing extraction turbine

0,45

Gas turbine with heat recovery

0,55

Internal combustion engine

0,75

If Member States introduce default values for power to heat ratios for units of type (f), (g), (h), (i), (j) and (k) referred to in Annex I, such default values shall be published and shall be notified to the Commission.

(c) If a share of the energy content of the fuel input to the cogeneration process is recovered in chemicals and recycled this share can be subtracted from the fuel input before calculating the overall efficiency used in paragraphs (a) and (b).

(d) Member States may determine the power to heat ratio as the ratio between electricity and useful heat when operating in cogeneration mode at a lower capacity using operational data of the specific unit.

▼M1

(e) The Commission shall establish detailed guidelines for the implementation and application of Annex II, including the determination of the power to heat ratio. Those measures, designed to amend non-essential elements of this Directive by supplementing it, shall be adopted in accordance with the regulatory procedure with scrutiny referred to in Article 14(2).

▼B

(f) Member States may use other reporting periods than one year for the purpose of the calculations according to paragraphs (a) and (b).